Rosemount , Rosemount transmitter, Hart 375, Hart 475, Rosemount 3051c, Rosemount 3051L, Rosemount 3051T, Rosemount 3051H, Rosemount 3051, Rosemount 3051s, Rosemount 3051ST, Rosemount 3051SL, Rosemount 3051SC, Rosemount 2051, Rosemount 2088, Rosemount 3144P, Rosemount 1151, Rosemount Vietnam, Rosemount Price
Chủ Nhật, 9 tháng 12, 2012
Micro Motion Rosemount Việt Nam | GNN Vietnam
Product Data Sheet
PS-00412, Rev. D
July 2006
ProLink
®
II
Transmitter configuration software tool
• Quick configuration for faster device commissioning
• Makes troubleshooting and diagnostics a snap
• View and log process data and meter status
• Easily download and save complete transmitter configurations
• Restore or configure transmittersfrom saved configuration files
2 ProLink II Transmitter Configuration Software Tool
ProLink
®
II transmitter configuration software tool
Transmitter configuration and data analysis
ProLink II delivers all the power and flexibility you
need to configure and manage Micro Motion
®
transmitters and analyze process data. ProLink II
provides an easy-to-use interface that allows you
to have your Micro Motion meter up and running
quickly no matter how complex your configuration
needs are. For times when you need a more
complete understanding of your meter’s flow
characteristics, ProLink II provides a window into
your process so you can easily see all process
variables, meter diagnostics, and alarm
conditions.
Making the connection
Making the initial transmitter connection is a
simple matter of selecting the appropriate
communication protocol, baud rate, parity, and
port number. You can connect over a network or
directly to the transmitter, using HART
®
, Modbus
®
,
or (with Micro Motion MVD
™
transmitters) the
Service Port. ProLink II automatically recognizes
your transmitter type and configuration, as well as
any installed applications such as petroleum
measurement.
The new 2.5 version of ProLink II supports the
new Model 2400S transmitter and expanded
functionality for Series 1000/2000 transmitters,
including meter verification—a unique new way of
documenting the structural integrity and
performance of Micro Motion meters.
A full list of supported Micro Motion transmitters is
provided on page 7.
ProLink II provides an easy-to-use interface.
ProLink II Transmitter Configuration Software Tool 3
Part of the AMS family
ProLink II is part of the
AMS family of products
from Emerson Process
Management. Whether you
are configuring a Micro
Motion transmitter with ProLink II or AMS, you will
see similar menus and have the same information
available. You can easily transfer knowledge
between ProLink II and the AMS environment
where you will also have the added benefits of
integrated device configuration, calibration, status,
an audit trail of device events, and an alert monitor
to detect and report status conditions.
A window into your process
ProLink II provides a process variable window that
shows you your key process information at a
glance. It can be more convenient to view process
variables in ProLink II as you investigate process
issues rather than walking the line to view
information from transmitters in the field.
Regardless of how you have configured your
transmitter’s outputs, ProLink II will always display
all the process variable information that the
transmitter has available, including totalizer and
inventory data.
AMS
ProLink II
Software
®
ProLink II shows important process
information at a glance.
4 ProLink II Transmitter Configuration Software Tool
Data Logger
The data logging feature
(1)
in ProLink II helps you
to chart and graph selected process, diagnostic,
and output variables.This look into time can help
you understand what is reallygoing on in the
process so you can determine techniques for
improving the productivity and quality of the
process. Data logged with the data logging tool
can be exported and viewed in an external
program (such as a spreadsheet application) so
that you can chart the data for further analysis.
Easy configuration
With ProLink II, you can quickly navigate to the
settings you need, because all configuration
information is collected into easy-to-use tabs.
Configuration changes are immediately
communicated to the transmitter, which allows you
to evaluate the effect of your changes and pick the
right settings for your process.
ProLink II can help configure multiple transmitters
easily. Using ProLink II, you can save a transmitter
configuration to a plain-text file and conveniently
send that same configuration to additional
transmitters directly fromthe file. This same
feature provides a convenient backup method for
all your transmitters.
The Data Logger helps improve overall productivity.
(1)
The data logging feature is not available for IFT9701, IFT9703, and RFT9712 transmitters.
ProLink II Transmitter Configuration Software Tool 5
Alarm handling
Alarm conditions are displayed by ProLink II on a
single 3-tab screen to make alarm troubleshooting
a fast and efficient process. Alarm information is
separated by severity into critical, informational,
and operational categories so that you can quickly
locate the source of the problem and understand
its priority instantly.
Transmitter troubleshooting
ProLink II can show you detailed information
about the raw signals being processed by a
transmitter, such as drive gain and pickoff values.
This kind of information can be extremely helpful
when troubleshooting transmitter behavior, which
minimizes expensive downtime.
Support for advanced transmitter
applications
If the transmitter has advanced functionality such
as Enhanced Density, Petroleum Measurement,
Discrete Batching, or Filling & Dosing software
installed, ProLink II will allow you to view and
configure these software options. The appropriate
tabs will automatically appear on the ProLink II
main screen if these options are supported by the
transmitter.
ProLink II supports the discrete batching
application on the Series 3000 transmitter and the
filling an dosing application on the Model 1500
transmitter.
• Define batches and fill targets
• Configure outputs for valve and pump control
• Start, stop, pause, and resume the batches
and fills
• Built-in overshoot compensation algorithms
Alarms are organized into three convenient tabs.
6 ProLink II Transmitter Configuration Software Tool
Pocket ProLink
ProLink is now available for the PocketPC
platform. Pocket Prolink allows you to take the
functionality of ProLink into the field easier than
ever before. Equipped with an adapter, a PDA with
Pocket ProLink can connect to and configure
nearly all of the same transmitters as ProLink II
but without the trouble of taking a laptop into the
field. Pocket ProLink can even communicate
wirelessly with Micro Motion Model 2400S Analog
transmitters using the IrDA port.
Accessories
ProLink II communicates serial data from your
computer to the transmitter’s RS-485 or 4–20 mA
terminals. Several types of signal converters and
adapters are available to help you make this
connection (e.g., convert from an RS-232 to an
RS-485 signal, or convert from a USB to an
RS-232 signal).
Micro Motion-recommended converters and
adapters can be ordered with ProLink II or Pocket
ProLink. Refer to the Ordering Information on
page 7.
ProLink II system requirements
The minimum system requirements for ProLink II
are listed in the table below.
Pocket ProLink system requirements
The minimum system requirements for Pocket
ProLink are listed below.
Pocket ProLink running on a Pocket PC device
Operating system requirements
Windows 98 or 98SE with 32 MB RAM
Windows ME with 64 MB RAM
Windows NT 4.0 (Service Pack 6a) with 64 MB RAM
Windows 2000 (Service Pack 3) with 128 MB RAM
Windows XP (Service Pack 1) with 128 MB RAM
Hardware requirements
Processor Pentium
®
-class 200 MHz or faster
RAM (See operating system requirements)
Disk space 15 MB
Video 1024 × 768 with 256 colors
CD-ROM drive 4× or faster
Serial port or
USB port
1 open port
Desktop requirements
A Windows computer capable of running ActiveSync
15 MB free disk space
PDA requirements
The following models are tested and supported:
• Compaq
®
iPAQ
™
3700, 3800, or 3900 series
•Hewlett-Packard®
iPAQ
™
4000 or 5000 series
•Dell®Axim
®
X30, X50, X5 or X3i
OS Windows CE v3.0
Ports Serial port required
Video High-resolution graphics support
ProLink II Transmitter Configuration Software Tool 7
Supported transmitters
The Micro Motion transmitters supported by
ProLink II and Pocket ProLink are:
Communication protocols
ProLink II can be used with the communication
protocols listed in the table below.
Ordering information
Supported transmitters
IFT9701
()
IFT9703
()
RFT9712
()
RFT9739
Model 1700/2700
Model 2400S
Model 1500/2500
LF-Series
MVD Direct Connect™
Series 3000 (MVD)
(1) ProLink II only.
Protocol Physical layer
HART Bell 202
RS-485
Modbus RS-485
Model Product description
PLK ProLink II software
Code ProLink II upgrade
0 ProLink II software (See system requirements on page 6)
1
(1)
(1) Requires completed Declaration of Ownership for prior version of ProLink
™
; available as software upgrade only.
Upgrade from ProLink to ProLink II
Code License
U Single user license (1 copy of ProLink II on a single computer)
Code Language
EEnglish FFrench GGerman
Code Accessories
A None
V
(2)
(2) Bell 202 and RS-485 signal converters sold by Micro Motion prior to April 01, 2001 are not compatible with the current version of
ProLink II. The signal converter must be capable of 2-wire half duplex asynchronous communication.
Viator RS-232 to Bell 202 HART Converter with tester and cables
M(2)
RS-232 to RS-485 Modbus/HART Converter with tester and cables
D Both RS-232 to Bell 202 and RS-232 to RS-485 Converters (options V & M)
E
(3)
(3) Only available with ProLink II upgrade option 0.
USB to Bell 202 HART Converter with tester and cables
F
(3)
USB to RS-485 Modbus or HART Converter with tester and cables
G
(3)
Both USB to Bell 202 and USB to RS-485 Converters (options E & F)
Typical model number: PLK 0 U E A
© 2006 Micro Motion, Inc. All rights reserved. PS-00412, Rev. D
Due to Micro Motion’s commitment to continuous improvement of our products, all specifications are subject to change without notice.
ELITE, ProLink, and the Micro Motion logo are registered trademarksof Micro Motion, Inc., Boulder, Colorado. MVD and MVD Direct Connect
are trademarks of Micro Motion, Inc., Boulder, Colorado. The Emerson logo is a trademark of Emerson Electric Co. All other trademarks are
property of their respective owners.
For the latest Micro Motion product specifications, view the
PRODUCTS section of our web site at www.micromotion.com
Micro Motion Inc. USA
Worldwide Headquarters
7070 Winchester Circle
Boulder, Colorado 80301
T (303) 527-5200
(800) 522-6277
F (303) 530-8459
Micro Motion Europe
Emerson Process Management
Wiltonstraat 30
3905 KW Veenendaal
The Netherlands
T +31 (0) 318 495 670
F +31 (0) 318 495 689
Micro Motion United Kingdom
Emerson Process Management Limited
Horsfield Way
Bredbury Industrial Estate
Stockport SK6 2SU U.K.
T 0870 240 1978
F 0800 966 181
Micro Motion Japan
Emerson Process Management
Shinagawa NF Bldg. 5F
1-2-5, Higashi Shinagawa
Shinagawa-ku
Tokyo 140-0002 Japan
T (81) 3 5769-6803
F (81) 3 5769-6843
Micro Motion Asia
Emerson Process Management
1 Pandan Crescent
Singapore 128461
Republic of Singapore
T (65) 6777-8211
F (65) 6770-8003