Notes:
  • Items are quoted per given model strings.
  • Calibration ranges are set to default, unless stated otherwise.
  • Item 1
    • Option 01 (3144PD6A2I1B5M5T1Q401K1105) is quoted as U1 [Dual Input Config, Hot Backup].
  • Items 2 and 3
    • Option 0408 (3051TG3A2B21KI1M6D0T1P10408S1A8092) is quoted as Q4Q8 [Calibration Certificate; Material Certificate].
    • Only the transmitter is quoted. Option S1 is removed as it calls for assembly to a Rosemount 1199 Seal. Kindly provide model or specifications for the seal if it is to be quoted.
  • Item 4
    • Invalid code 0 is removed. (3051TG4A2B31KI1M6D00T1P0408S5A8092)
    • Invalid code P (3051TG4A2B31KI1M6D00T1P0408S5A8092) is quoted as P1 [Hydrostatic Testing].
    • Option 0408 (3051TG4A2B31KI1M6D00T1P0408S5A8092) is quoted as Q4Q8 [Calibration Certificate; Material Certificate].
    • Only the transmitter is quoted. Option S5 is removed as it calls for assembly to an integral manifold. Kindly provide the model or specifications of the manifold if it is to be quoted.
  • Item 5
    • Invalid code M (0065G22F0110N0310MG3W0043) is removed.
  • Item 6
    • Only the transmitter is quoted. Option S5 is removed as it calls for assembly to an integral manifold. Kindly provide the model or specifications of the manifold if it is to be quoted.
    • Calibration range used is the provided value of 0 – 220 Barg.
  • Item 7
    • Option 04 (3144PD2A1MM5T1C204XA) is quoted as Q4 [Calibration Certificate].
    • Only the transmitter is quoted. Option XA is removed as it calls for assembly to a sensor. Kindly provide the model or specifications of the sensor if it is to be quoted.
    • Invalid code M is removed (3144PD2A1MM5T1C204XA).
    • Product certification offered is NA (No Approval).
    • The item’s default device configuration is for use with a Pt 100, 4-Wire sensor (Sensor Limit: -200 to 850°C). Upon order, kindly provide the sensor type to be used with the transmitter.
  • Item 8
    • Only the transmitter is quoted. Option XA is removed as it calls for assembly to a sensor. Kindly provide the model or specifications of the sensor if it is to be quoted.
    • Calibration range used is the provided value of 0 – 80°C.
  • Item 9
    • Only the transmitter is quoted. Option XA is removed as it calls for assembly to a sensor. Kindly provide the model or specifications of the sensor if it is to be quoted.
    • The item’s default device configuration is for use with a Pt 100, 4-Wire sensor (Sensor Limit: -200 to 850°C). Upon order, kindly provide the sensor type to be used with the transmitter.
  • Item 10
    • Only the transmitter is quoted. Option S5 is removed as it calls for assembly to an integral manifold. Kindly provide the model or specifications of the manifold if it is to be quoted.
    • Invalid code 1 is removed (2051TG3A2B21KS51M5P1Q4).
    • Calibration range used is the provided value of 0 – 18 Barg.